PROPERTIES:

Cable Diameter: 0.359” +0.004” - 0.002” (9.12mm + 0.10mm -0.05mm)
Minimum Sheave Diameter: 26” (66 cm)
Cable Stretch Coefficient: 1.55 ft/Kft/Klbs (1.74 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 15
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 1000VDC (457 MegaΩ/Km @ 1000VDC)
Armor Electrical Resistance: 4.5 Ω/Kft (14.76 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 9000 lbs (40.0 KN) Nominal
Maximum Suggested Working Tension: 5000 lbs (22.2 KN)
Number and Size of Wires:
Inner Armor 11 x 0.0470” (1.194 mm)
Outer Armor 14 x 3W Strand .0430 (1.092 mm)
Average Wire Breaking Strength:
Inner Armor 542 lbs (2.4 KN)
Outer Armor 191 lbs (0.85 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachJacket TypeIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
 lbs/Kft
Kg/Km
1Q36PTZ-EHStZ4
ETFE0.019
0.483
19x0.0142
19x0.361
2.8
0.2
54
177
0.136
3.454
171
232
141
168
400*
204*
FEP0.0135
0.343
19x0.0142
10x0.361
2.8
9.2
54
177
0.098
2.489
171
232
141
168

* See attached specification sheet for recommended maximum temperature exposure times.

  • The EcoSeal® features an “inside out” polymer-filled technology consisting of a homogenous outer armor and jacketing layer, utilizing a
  • proprietary polymer.
  • Core assembly – Copper strand consists of nineteen wires around one center wire. Conductor resistance is measured at 68 °F.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.
  • Not recommended for use in any sour and / or corrosive environment.


View Product Specification Sheet