Camesa
Camesa EMC Banner 3

EMC Product Catalog

5/16" (8.18 mm) Monoconductor 1N32

5/16" (8.18 mm) Monoconductor 1N32

PROPERTIES:

Cable Diameter: 0.322” +0.005” - 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 18” (46 cm)
Cable Stretch Coefficient: 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 15
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 12,000 lbs (53.3 KN) Nominal
Maximum Suggested Working Tension: 6,000 lbs (26.6 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0445” (1.130 mm)
Outer Armor 18 x 0.0445” (1.130 mm)
Average Wire Breaking Strength:
Inner Armor 442 lbs (1.97 KN)
Outer Armor 442 lbs (1.97 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N32PP300
149
Poly0.042
1.067
19x0.0142
19x0.361
2.8
9.2
46
151
0.155
3.937
187
278
155
230
1N32PXZ420
216
Camtane0.022
0.560
19x0.0142
19x0.361
2.8
9.2
47
154
0.115
2.921
189
282
157
233
420
216
ETFE0.0200
0.508
19x0.0142
19x0.361
2.8
9.2
47
154
0.155
3.937
189
282
157
233
1N32PTZ500
260
FEP0.0245
0.622
19x0.0142
19x0.361
2.8
9.2
45
148
0.120
3.048
194
288
160
238
500
260
ETFE0.0175
0.445
19x0.0142
19.0x361
2.8
9.2
45
148
0.155
3.937
194
288
160
238

* See attached specification sheet for recommended maximum temperature exposure times.

  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.