1/8” (3.20 mm) Monoconductor 1N12

1/8” (3.20 mm) Monoconductor 1N12

PROPERTIES:

Cable Diameter: 0.126” +0.004” -0.002” (3.20mm + 0.10mm -0.05mm)
Minimum Sheave Diameter: 7” (18 cm)
Cable Stretch Coefficient: 6.5 ft/Kft/Klbs (7.3 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 300 VDC
Conductor AWG Rating: 24
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 1000VDC (457 MegaΩ/Km @ 1000VDC)
Armor Electrical Resistance: 13.0 Ω/Kft (42.7 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 1,600 lbs (7.1 KN) Nominal
Maximum Suggested Working Tension: 800 lbs (3.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0175” (0.444 mm)
Outer Armor 18 x 0.0175” (0.444 mm)
Average Wire Breaking Strength:
Inner Armor 65 lbs (0.29 KN)
Outer Armor 65 lbs (0.29 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N12RP300
149
Poly0.0175
0.444
7x0.0085
7x0.216
21.0
69.0
41
134
0.060
1.524
28
42
23
35
N/A
1N12RZ500*
260*
ETFE0.0175
0.444
7x0.0085
7x0.216
21.0
69.0
48
157
0.060
1.524
29
43
24
36
N/A

* See attached specification sheet for recommended maximum temperature exposure times. 

  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.
  • Not for use in oil and gas wells. 


View Product Specification Sheet