PROPERTIES:

Cable Diameter: 0.185” +0.004” -0.002” (4.70mm + 0.10mm -0.05mm)
Minimum Sheave Diameter: 14” (36 cm)
Cable Stretch Coefficient: 3.0 ft/Kft/Klbs (3.37 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,000 VDC
Conductor AWG Rating: 20
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 1000VDC (457 MegaΩ/Km @ 1000VDC)
Armor Electrical Resistance: 6.0 Ω/Kft (19.7 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 4,000 lbs (17.8 KN) Nominal
Maximum Suggested Working Tension: 2,000 lbs (8.9 KN) Nominal
Number and Size of Wires:
Inner Armor 12 x 0.0220” (0.559 mm)
Outer Armor 12 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 103 lbs (0.46 KN)
Outer Armor 272 lbs (1.21 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1L18RP300*
149*
Poly0.019
0.483
7x0.0128
7x0.325
9.4
30.8
53
174
0.076
1.930
65
97
54
80
1L18RZ500*
260*
ETFE0.019
0.483
7x0.0128
7x0.325
9.4
30.8
63
207
0.076
1.930
66
99
55
81

* See attached specification sheet for recommended maximum temperature exposure times. 

  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.