Camesa

Camesa Contact Us - Phone Call us at +1(281) 344-0905,
Camesa Contact Us - Envelope E-mail us, or
Find a Distributor

To access a complete listing of Camesa® wire and wire rope products, please visit: www.CamesaWire.com

Camesa EMC Banner 1

EMC Product Catalog

0.490” (12.45 mm) 7-Conductor Extra High Strength 7Q49-EHS

0.490” (12.45 mm) 7-Conductor Extra High Strength 7Q49-EHS

PROPERTIES:

Cable Diameter: 0.490” +0.006” - 0.003” (12.45mm + 0.15mm -0.076mm)
Minimum Sheave Diameter: 25” (64 cm)
Cable Stretch Coefficient: 0.60 ft/Kft/Klbs (0.67 m/km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1200 VDC
Conductor AWG Rating: 20
Minimum Insulation Resistance: 1,500 MegΩ/Kft @ 500 VDC (457 MegΩ/Km @ 500 VDC)
Armor Electrical Resistance: 1.0 Ω/Kft (3.3 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 25,750 lbs (114.6 KN)
Maximum Suggested Working Tension: 12,875 lbs (57.3 KN)
Number and Size of Wires:
Inner Armor 20 x 0.0460” (1.17 mm)
Outer Armor 20 x 0.0620” (1.57 mm)
Average Wire Breaking Strength:
Inner Armor 532 lbs (2.4 KN)
Outer Armor 966 lbs (4.3 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachJacket TypeIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
 lbs/Kft
Kg/Km
7Q49RTZZ-EHS500*
260*
FEP0.0130
0.330
7x0.0128
7x0.325
9.8
32.2
27
89
0.064
1.626
ETFE409
609
338
503
N/A
500*
260*
ETFE0.0100
0.254
7x9.0128
7x0.325
9.8
32.2
27
89
0.084
2.134
ETFE409
609
338
503
N/A

* See attached specification sheet for recommended maximum temperature exposure times.

  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68° F.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • Center conductor construction is 7x0.0142” with a non-conductive center member. The typical resistance is reduced by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer conductors.
  • All values shown are nominal or typical values.


View Product Specification Sheet