Camesa

Camesa Contact Us - Phone Call us at +1(281) 344-0905,
Camesa Contact Us - Envelope E-mail us, or
Find a Distributor

To access a complete listing of Camesa® wire and wire rope products, please visit: www.CamesaWire.com

Camesa EMC Banner 5

EMC Product Catalog

7/16” (10.82mm) 7-Conductor 7H42

7/16” (10.82mm) 7-Conductor 7H42

PROPERTIES:

Cable Diameter: 0.426” +0.005” - 0.002” (10.82mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 24” (61 cm)
Cable Stretch Coefficient: 0.75 ft/Kft/Klbs (0.84 m/km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1000 VDC
Conductor AWG Rating: 20
Minimum Insulation Resistance: 1,500 MegΩ/Kft @ 1000VDC (457 MegΩ/Km @ 1000VDC)
Armor Electrical Resistance: 1.2 Ω/Kft (3.9 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 17,600 lbs (78.3 KN) Nominal
Maximum Suggested Working Tension: 8,800 lbs (39.2 KN)
Number and Size of Wires:
Inner Armor 18 x 0.0425” (1.080 mm)
Outer Armor 18 x 0.0585” (1.490 mm)
Average Wire Breaking Strength:
Inner Armor 404 lbs (1.80 KN)
Outer Armor 765 lbs (3.40 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachTape TypeIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
 lbs/Kft
Kg/Km
7H42RP300*
149*
Poly0.018
0.457
7x0.0128
7x0.325
9.8
32.2
53
174
0.074
1.880
Dacron®309
460
256
380
7H42RZ500*
260*
ETFE0.0180
0.457
7x0.0128
7x0.325
9.8
32.2
62
203
0.074
1.880
Dacron® *316
471
261
389

* See attached specification sheet for recommended maximum temperature exposure times.

  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
  • Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68° F.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • Center conductor construction is 7×0.0128”. The typical capacitance is decreased by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer conductors.
  • All values shown are nominal or typical values.
  • Dacron® does not withstand temperatures exceeding 300°F. Nomex® is available by customer request at time of order for additional cost.


View Product Specification Sheet