Camesa

Camesa Contact Us - Phone Call us at +1(281) 344-0905,
Camesa Contact Us - Envelope E-mail us, or
Find a Distributor

To access a complete listing of Camesa® wire and wire rope products, please visit: www.CamesaWire.com

Camesa EMC Banner 4

EMC Product Catalog

0.377” (9.58 mm) 3-Conductor Cable 3Q37

0.377” (9.58 mm) 3-Conductor Cable 3Q37

PROPERTIES:

Cable Diameter: 0.377 +0.005” - 0.002” (9.58 mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 22” (56 cm)
Cable Stretch Coefficient: 1.6 ft/Kft/Klbs (1.8 m/km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1200 VDC
Conductor AWG Rating: 18
Minimum Insulation Resistance: 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.7 Ω/Kft (5.6 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 13,200 lbs (58.74 KN) Nominal
Maximum Suggested Working Tension: 6,600 lbs (29.37 KN)
Number and Size of Wires:
Inner Armor 16 x 0.0425” (1.08 mm)
Outer Armor 20 x 0.0470” (1.19 mm)
Average Wire Breaking Strength:
Inner Armor 383 lbs (1.71 KN)
Outer Armor 469 lbs (2.09 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachTape TypeIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
 lbs/Kft
Kg/Km
3Q37RP300*
149*
Poly0.0230
0.584
7x0.0152
7x0.386
7.1
23.3
47
154
0.096
2.438
Dacron®233
347
49
74
N/A

* See attached specification sheet for recommended maximum temperature exposure times.

  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
  • Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68° F.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.
  • Dacron® does not withstand temperatures exceeding 300°F. Nomex® is available by customer request at time of order for additional cost.


View Product Specification Sheet